{"id":122,"date":"2026-06-14T16:56:00","date_gmt":"2026-06-14T16:56:00","guid":{"rendered":"https:\/\/rdp.in\/gpu-mart\/product\/rdp-direct-liquid-cooling-kit-pro\/"},"modified":"2026-07-05T09:21:41","modified_gmt":"2026-07-05T09:21:41","slug":"draco-700-kw-in-row-cdu","status":"publish","type":"product","link":"https:\/\/rdp.in\/gpu-mart\/product\/draco-700-kw-in-row-cdu\/","title":{"rendered":"DRACO 700 kW In-Row CDU"},"content":{"rendered":"<p>The DRACO 700 kW In-Row CDU is a high-capacity coolant distribution unit that cools a row of dense GPU racks \u2014 700 kW of heat removal via liquid-to-liquid cdu (in-row), so racks of 700 W\u20131 kW+ GPUs run at full clocks. It is the thermal backbone that makes high-density AI deployments possible on-premises, in INR, on a GST invoice.<\/p>\n<p>Engineered to match RDP&#8217;s rack-scale systems and superclusters, it isolates the rack coolant loop from facility water, controls flow, temperature and pressure, filters the coolant, and distributes it to the cold-plate loops \u2014 delivered sized, plumbed and validated with the compute it cools, with leak detection and monitoring built in.<\/p>\n<h3>Key highlights<\/h3>\n<ul>\n<li><strong>700 kW \u00b7 Up to 1,100 L\/min<\/strong> \u2014 row-scale heat removal for Up to 6 dense racks.<\/li>\n<li><strong>Liquid-to-liquid CDU (in-row)<\/strong> \u2014 isolates rack coolant from facility water; controls flow, temperature and pressure with filtration.<\/li>\n<li><strong>PG25 \/ treated water<\/strong> \u2014 corrosion-safe coolant chemistry for reliable long-term operation.<\/li>\n<li><strong>Redundant pumps<\/strong> \u2014 N+1 pumping for continuous cooling during maintenance.<\/li>\n<li><strong>Leak detection &amp; monitoring<\/strong> \u2014 sensors and BMS\/DCIM integration for safe, observable operation.<\/li>\n<li><strong>Efficient, low PUE<\/strong> \u2014 liquid moves heat far more efficiently than air, lowering fan power and energy cost.<\/li>\n<li><strong>Validated with RDP compute<\/strong> \u2014 delivered as part of a tested, cooled deployment.<\/li>\n<li><strong>Make-in-India OEM<\/strong> \u2014 predictable INR pricing, GST tax invoice, pan-India onsite support, GeM-procurable.<\/li>\n<\/ul>\n<h3>Where it fits<\/h3>\n<ul>\n<li><strong>Dense GPU rows (primary):<\/strong> distributes coolant to direct-to-chip cold-plate loops across Up to 6 dense racks.<\/li>\n<li><strong>Rack-scale &amp; NVL systems:<\/strong> the cooling that keeps rows of NVL72-class racks within thermal limits.<\/li>\n<li><strong>New liquid-cooled halls:<\/strong> the row\/zone CDU layer between racks and facility water.<\/li>\n<li><strong>Scale-up cooling:<\/strong> add CDUs as rows and density grow.<\/li>\n<\/ul>\n<h3>How it works<\/h3>\n<p>The CDU forms a closed technology-cooling-system (TCS) loop to the racks, rejecting heat to the facility water loop through a heat exchanger. It controls flow, supply temperature and pressure, filters and treats the coolant, and provides redundant pumping. RDP sizes the CDU, loop and connections to your row density and facility water conditions. <em>Honest note: real cooling capacity depends on inlet water temperature, flow and rack layout \u2014 we size and validate it for your room.<\/em><\/p>\n<h3>Industry use cases<\/h3>\n<ul>\n<li><strong>AI data centres<\/strong> \u2014 cool rows of dense GPU and NVL racks at full clocks.<\/li>\n<li><strong>Government &amp; national labs<\/strong> \u2014 sovereign HPC\/AI cooling at scale.<\/li>\n<li><strong>Neocloud \/ AI providers<\/strong> \u2014 higher density per row, lower PUE.<\/li>\n<li><strong>Manufacturing &amp; energy<\/strong> \u2014 large HPC + AI thermal management.<\/li>\n<li><strong>Colocation<\/strong> \u2014 liquid-ready density in shared halls.<\/li>\n<li><strong>Research &amp; higher-ed<\/strong> \u2014 efficient cooling for large clusters.<\/li>\n<\/ul>\n<h3>Performance \u2014 and how to be sure<\/h3>\n<p>We don&#8217;t publish inflated peak numbers. The honest picture: 700 kW at Up to 1,100 L\/min cools rows of dense AI racks within thermal limits given suitable facility water. <strong>Want certainty? Request a thermal assessment of your rows and facility before you buy<\/strong>; we&#8217;ll size the CDU and confirm the cooling capacity at your conditions.<\/p>\n<h3>Series &amp; scale path<\/h3>\n<ul>\n<li><strong>DRACO<\/strong> (flagship thermal tier) \u2014 <em>this<\/em>.<\/li>\n<li><strong>Capacity ladder:<\/strong> rear-door HX \u2192 in-rack\/in-row CDU \u2192 row CDU \u2192 facility CDU (MW-scale).<\/li>\n<li><strong>When to step up:<\/strong> add CDUs or move to a facility-scale unit as density rises \u2014 talk to an architect about the loop.<\/li>\n<\/ul>\n<h3>Liquid vs air \u2014 the efficiency case<\/h3>\n<p>At 700 W\u20131 kW+ per GPU, air cooling hits its limit; liquid removes heat far more efficiently, enabling higher density, full clocks and lower PUE \u2014 and quieter rooms. The result is more compute per row and lower energy cost. RDP pricing is fixed in INR with a GST input-credit-eligible invoice \u2014 ask for a <strong>PUE and density comparison<\/strong> for your facility.<\/p>\n<h3>Software &amp; integration<\/h3>\n<p>Integrates with your facility: BMS\/DCIM monitoring, leak detection, flow\/temperature\/pressure telemetry, redundant-pump control and alarms. Designed to match RDP rack-scale systems and superclusters and standard facility water loops.<\/p>\n<h3>Power, cooling &amp; facility integration<\/h3>\n<p>A In-row (full-height) unit \u2014 plan facility water (supply\/return temperature and flow), power for pumps\/controls, and floor integration. <em>(Exact capacity, flow, pressure-drop and connection figures confirmed in the thermal design.)<\/em> N+1 pumps and full monitoring.<\/p>\n<h3>Deployment, warranty &amp; support<\/h3>\n<ul>\n<li><strong>Made to order<\/strong>, sized, plumbed and commissioned in India with the compute it cools; lead time confirmed at quote.<\/li>\n<li><strong>In the box:<\/strong> CDU, pumps, heat exchanger, fittings, sensors and controls; facility connection scoped at quote.<\/li>\n<li><strong>Onsite warranty + AMC<\/strong> with pan-India coverage and an RMA\/escalation path <em>(exact terms confirmed at quote)<\/em>.<\/li>\n<\/ul>\n<h3>Why RDP<\/h3>\n<p>14 years of Make-in-India infrastructure and <strong>300,000+ devices shipped<\/strong>. Indian OEM, INR pricing, GST tax invoice, pan-India onsite engineers, GeM availability, and DPDP \/ sovereign-AI-ready deployment.<\/p>\n<h3>Buy with confidence<\/h3>\n<p>This is row-scale AI cooling, made to order \u2014 <strong>talk to an RDP solution architect<\/strong>, get a thermal assessment and CDU sizing for your rows and facility, and a PUE comparison <strong>before you commit.<\/strong> Request a quote to begin.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>700 kW \u00b7 Up to 1,100 L\/min \u00b7 Liquid-to-liquid CDU (in-row) \u00b7 PG25 \/ treated water \u00b7 In-row (full-height)<\/p>\n","protected":false},"featured_media":2132,"comment_status":"open","ping_status":"closed","template":"","meta":{"_yoast_wpseo_title":"","_yoast_wpseo_metadesc":"","rank_math_title":"DRACO 700 kW In-Row CDU \u2014 700 kW, Liquid-to-liquid CDU (in-row) | RDP GPU Mart","rank_math_description":"AI row liquid cooling \u2014 700 kW, Liquid-to-liquid CDU (in-row), PG25 \/ treated water. Cool rows of dense GPU racks at full clocks, lower PUE. Make-in-India, GST invoice. Request a quote.","_hermes_jsonld":""},"product_brand":[],"product_cat":[26],"product_tag":[83],"class_list":["post-122","product","type-product","status-publish","has-post-thumbnail","product_cat-liquid-cooling-thermal","product_tag-ready-to-buy","pa_form-factor-floor-standing","pa_industry-enterprise-gccs","pa_industry-neocloud","pa_industry-public-sector-sovereign-ai","pa_series-draco","first","onbackorder","taxable","shipping-taxable","product-type-simple"],"_links":{"self":[{"href":"https:\/\/rdp.in\/gpu-mart\/wp-json\/wp\/v2\/product\/122","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/rdp.in\/gpu-mart\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/rdp.in\/gpu-mart\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/rdp.in\/gpu-mart\/wp-json\/wp\/v2\/comments?post=122"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/rdp.in\/gpu-mart\/wp-json\/wp\/v2\/media\/2132"}],"wp:attachment":[{"href":"https:\/\/rdp.in\/gpu-mart\/wp-json\/wp\/v2\/media?parent=122"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/rdp.in\/gpu-mart\/wp-json\/wp\/v2\/product_brand?post=122"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/rdp.in\/gpu-mart\/wp-json\/wp\/v2\/product_cat?post=122"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/rdp.in\/gpu-mart\/wp-json\/wp\/v2\/product_tag?post=122"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}