{"id":124,"date":"2026-06-14T16:56:00","date_gmt":"2026-06-14T16:56:00","guid":{"rendered":"https:\/\/rdp.in\/gpu-mart\/product\/rdp-direct-liquid-cooling-kit-xl\/"},"modified":"2026-07-05T09:21:41","modified_gmt":"2026-07-05T09:21:41","slug":"draco-2-5-mw-facility-cdu","status":"publish","type":"product","link":"https:\/\/rdp.in\/gpu-mart\/product\/draco-2-5-mw-facility-cdu\/","title":{"rendered":"DRACO 2.5 MW Facility CDU"},"content":{"rendered":"<p>The DRACO 2.5 MW Facility CDU is RDP&#8217;s flagship coolant distribution unit \u2014 2.5 MW of heat removal that cools a full row-zone or a data-hall block of dense GPU racks. It is the facility-scale thermal backbone that makes the largest on-premises AI deployments possible, in INR, on a GST invoice.<\/p>\n<p>Engineered to match RDP&#8217;s rack-scale systems, superclusters and supercomputers, it isolates the rack coolant loops from facility water, controls flow, temperature and pressure, filters the coolant, and distributes it across many racks with N+1 pumping \u2014 delivered sized, plumbed and commissioned with the compute it cools, with leak detection and monitoring built in.<\/p>\n<h3>Key highlights<\/h3>\n<ul>\n<li><strong>2.5 MW \u00b7 Up to 4,000 L\/min<\/strong> \u2014 facility-scale heat removal for Up to 24 dense racks \/ a row-zone.<\/li>\n<li><strong>Liquid-to-liquid facility CDU<\/strong> \u2014 isolates rack coolant from facility water; controls flow, temperature and pressure with filtration at scale.<\/li>\n<li><strong>PG25 \/ treated water<\/strong> \u2014 corrosion-safe coolant chemistry for reliable long-term operation.<\/li>\n<li><strong>N+1 redundant pumps<\/strong> \u2014 continuous cooling during maintenance and failures.<\/li>\n<li><strong>Leak detection &amp; monitoring<\/strong> \u2014 sensors and BMS\/DCIM integration for safe, observable operation at scale.<\/li>\n<li><strong>Efficient, low PUE<\/strong> \u2014 liquid removes heat far more efficiently than air across the hall.<\/li>\n<li><strong>Validated with RDP compute<\/strong> \u2014 delivered as part of a tested, cooled data hall.<\/li>\n<li><strong>Make-in-India OEM<\/strong> \u2014 predictable INR pricing, GST tax invoice, pan-India onsite support, GeM-procurable.<\/li>\n<\/ul>\n<h3>Where it fits<\/h3>\n<ul>\n<li><strong>Data-hall cooling (primary):<\/strong> distributes coolant to direct-to-chip loops across Up to 24 dense racks \/ a row-zone.<\/li>\n<li><strong>Superclusters &amp; supercomputers:<\/strong> the cooling backbone for halls of NVL72-class racks.<\/li>\n<li><strong>New liquid-cooled facilities:<\/strong> the facility CDU layer between the racks and the building&#8217;s water loop.<\/li>\n<li><strong>Scale-up cooling:<\/strong> add CDUs as the data hall grows.<\/li>\n<\/ul>\n<h3>How it works<\/h3>\n<p>The facility CDU forms a closed technology-cooling-system (TCS) loop to many racks, rejecting heat to the building water loop through large heat exchangers. It controls flow, supply temperature and pressure, filters and treats the coolant, and provides N+1 pumping for continuous operation. RDP sizes the CDU, loops and connections to your hall density and facility water conditions. <em>Honest note: real cooling capacity depends on inlet water temperature, flow and hall layout \u2014 we size and validate it for your facility.<\/em><\/p>\n<h3>Industry use cases<\/h3>\n<ul>\n<li><strong>AI data centres<\/strong> \u2014 cool halls of dense GPU and NVL racks at full clocks.<\/li>\n<li><strong>Government &amp; national labs<\/strong> \u2014 sovereign HPC\/AI cooling at facility scale.<\/li>\n<li><strong>Neocloud \/ hyperscale operators<\/strong> \u2014 facility-scale density and low PUE.<\/li>\n<li><strong>Large enterprise &amp; energy<\/strong> \u2014 the largest HPC + AI thermal deployments.<\/li>\n<li><strong>Colocation<\/strong> \u2014 liquid-ready density across shared halls.<\/li>\n<li><strong>National research programmes<\/strong> \u2014 cooling for the largest clusters.<\/li>\n<\/ul>\n<h3>Performance \u2014 and how to be sure<\/h3>\n<p>We don&#8217;t publish inflated peak numbers. The honest picture: 2.5 MW at Up to 4,000 L\/min cools a row-zone of dense AI racks within thermal limits given suitable facility water. <strong>Want certainty? Request a thermal assessment of your hall and facility before you buy<\/strong>; we&#8217;ll size the CDU and confirm the cooling capacity at your conditions.<\/p>\n<h3>Series &amp; scale path<\/h3>\n<ul>\n<li><strong>DRACO<\/strong> (flagship thermal tier) \u2014 <em>this, the largest in the line<\/em>.<\/li>\n<li><strong>Capacity ladder:<\/strong> rear-door HX \u2192 in-rack\/in-row CDU \u2192 row CDU \u2192 facility CDU (MW-scale).<\/li>\n<li><strong>When to step up:<\/strong> add facility CDUs as the hall grows \u2014 talk to an architect about the loop and redundancy.<\/li>\n<\/ul>\n<h3>Liquid vs air \u2014 the efficiency case<\/h3>\n<p>At 700 W\u20131 kW+ per GPU, air cooling hits its limit; liquid removes heat far more efficiently across the hall, enabling higher density, full clocks and lower PUE. The result is more compute per facility and lower energy cost. RDP pricing is fixed in INR with a GST input-credit-eligible invoice \u2014 ask for a <strong>PUE and density comparison<\/strong> for your facility.<\/p>\n<h3>Software &amp; integration<\/h3>\n<p>Integrates with your facility: BMS\/DCIM monitoring, leak detection, flow\/temperature\/pressure telemetry, N+1-pump control and alarms. Designed to match RDP rack-scale systems, superclusters and supercomputers and standard facility water loops.<\/p>\n<h3>Power, cooling &amp; facility integration<\/h3>\n<p>A Facility CDU (floor-standing, N+1) unit \u2014 plan facility water (supply\/return temperature and flow), power for pumps\/controls, and floor integration with redundancy. <em>(Exact capacity, flow, pressure-drop and connection figures confirmed in the thermal design.)<\/em> N+1 pumps and full monitoring.<\/p>\n<h3>Deployment, warranty &amp; support<\/h3>\n<ul>\n<li><strong>Made to order<\/strong>, sized, plumbed and commissioned in India with the compute it cools; project timeline confirmed at quote.<\/li>\n<li><strong>In the box:<\/strong> facility CDU, pumps, heat exchangers, fittings, sensors and controls; facility connection scoped at quote.<\/li>\n<li><strong>Onsite warranty + AMC<\/strong> with pan-India coverage and an RMA\/escalation path <em>(exact terms confirmed at quote)<\/em>.<\/li>\n<\/ul>\n<h3>Why RDP<\/h3>\n<p>14 years of Make-in-India infrastructure and <strong>300,000+ devices shipped<\/strong>. Indian OEM, INR pricing, GST tax invoice, pan-India onsite engineers, GeM availability, and DPDP \/ sovereign-AI-ready deployment.<\/p>\n<h3>Buy with confidence<\/h3>\n<p>This is facility-scale AI cooling, made to order \u2014 <strong>talk to an RDP solution architect<\/strong>, get a thermal assessment and CDU sizing for your hall and facility, and a PUE comparison <strong>before you commit.<\/strong> Request a quote to begin.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>2.5 MW \u00b7 Up to 4,000 L\/min \u00b7 Liquid-to-liquid facility CDU \u00b7 PG25 \/ treated water \u00b7 Facility CDU (floor-standing, N+1)<\/p>\n","protected":false},"featured_media":1962,"comment_status":"open","ping_status":"closed","template":"","meta":{"_yoast_wpseo_title":"","_yoast_wpseo_metadesc":"","rank_math_title":"DRACO 2.5 MW Facility CDU \u2014 2.5 MW, facility CDU | RDP GPU Mart","rank_math_description":"Facility-scale AI cooling \u2014 2.5 MW, Liquid-to-liquid facility CDU, PG25 \/ treated water, N+1 pumps. Cool a data hall of dense GPU racks, lower PUE. Make-in-India, GST invoice. Request a quote.","_hermes_jsonld":""},"product_brand":[],"product_cat":[26],"product_tag":[],"class_list":["post-124","product","type-product","status-publish","has-post-thumbnail","product_cat-liquid-cooling-thermal","pa_form-factor-floor-standing","pa_industry-enterprise-gccs","pa_industry-neocloud","pa_industry-public-sector-sovereign-ai","pa_series-draco","first","instock","taxable","shipping-taxable","product-type-external"],"_links":{"self":[{"href":"https:\/\/rdp.in\/gpu-mart\/wp-json\/wp\/v2\/product\/124","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/rdp.in\/gpu-mart\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/rdp.in\/gpu-mart\/wp-json\/wp\/v2\/types\/product"}],"replies":[{"embeddable":true,"href":"https:\/\/rdp.in\/gpu-mart\/wp-json\/wp\/v2\/comments?post=124"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/rdp.in\/gpu-mart\/wp-json\/wp\/v2\/media\/1962"}],"wp:attachment":[{"href":"https:\/\/rdp.in\/gpu-mart\/wp-json\/wp\/v2\/media?parent=124"}],"wp:term":[{"taxonomy":"product_brand","embeddable":true,"href":"https:\/\/rdp.in\/gpu-mart\/wp-json\/wp\/v2\/product_brand?post=124"},{"taxonomy":"product_cat","embeddable":true,"href":"https:\/\/rdp.in\/gpu-mart\/wp-json\/wp\/v2\/product_cat?post=124"},{"taxonomy":"product_tag","embeddable":true,"href":"https:\/\/rdp.in\/gpu-mart\/wp-json\/wp\/v2\/product_tag?post=124"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}