

DRACO 64-Port 800G InfiniBand Switch
64× 800G OSFP (XDR) · 102 Tb/s switching · InfiniBand XDR (Quantum-X800 class) · <600 ns port-to-port · 1U
Key Specifications
See full specs ↓“RDP delivered and installed our edge AI pods across 6 sites with predictable INR pricing and onsite SLA.” — [customer / sector, to confirm]


Designed, built and supported in India — sovereign by design
Your AI factory on sovereign Indian infrastructure: data residency under DPDP, MeitY-recognised, ISO 27001 / SOC 2 deployment paths, and procurement on GeM.
Overview
The DRACO 64-Port 800G InfiniBand Switch is the high-bandwidth interconnect that turns a pile of GPU servers into a cluster. It provides 64× 800G OSFP (XDR) at 102 Tb/s of non-blocking switching over InfiniBand XDR (Quantum-X800 class), with <600 ns port-to-port — the low-latency, lossless fabric that lets distributed AI training scale across nodes without the network becoming the bottleneck. On-premises, in INR, on a GST invoice.
Engineered as the fabric layer of an RDP AI cluster, it carries the collective (all-reduce) traffic that dominates multi-node training, and is delivered configured, cabled and validated alongside the compute and storage it connects.
Key highlights
- 64× 800G OSFP (XDR) · 102 Tb/s — non-blocking switching to wire a GPU cluster at full bandwidth.
- InfiniBand XDR (Quantum-X800 class) — RDMA, lossless, in-network compute (SHARP) for fast collectives.
- <600 ns port-to-port — low latency so distributed training scales with near-linear efficiency.
- 800G / 400G per port — flexible speeds to match your GPU NICs/DPUs.
- Spine-leaf ready — combine switches into a non-blocking fabric for hundreds to thousands of GPUs.
- Validated with RDP compute — delivered as part of a tested cluster, not a loose box.
- On-prem sovereignty — your fabric, your data path; DPDP-friendly, air-gappable.
- Make-in-India OEM — predictable INR pricing, GST tax invoice (HSN 8517), pan-India onsite support, GeM-procurable.
Where it fits
- GPU cluster fabric (primary): the interconnect between GPU servers that carries distributed-training collectives.
- Storage fabric: high-bandwidth path between GPU nodes and the NVMe parallel-FS (GPUDirect).
- Scale-out spine: a leaf or spine in a non-blocking topology for large clusters.
- HPC interconnect: tightly-coupled MPI and AI collectives.
How it works
The switch forms a leaf/spine fabric with RDMA over InfiniBand; GPU NICs/DPUs connect at 800G / 400G. In-network compute (SHARP) offloads reductions, and adaptive routing avoids hotspots — so all-reduce traffic, which dominates multi-node training, completes fast. RDP sizes the topology (oversubscription, spine count) to your cluster. Honest note: real scaling efficiency depends on topology, collective library and model — we validate it on your cluster, not just a peak port number.
Industry use cases
- AI/ML & foundation-model teams — the fabric that lets training scale across nodes.
- Government & national labs — sovereign HPC/AI interconnect.
- Neocloud / AI providers — the fabric layer of a GPU cloud.
- BFSI & research — low-latency clusters for training and HPC.
- Telecom — high-bandwidth AI fabric at core/edge.
- Manufacturing & energy — HPC + AI cluster interconnect.
Performance — and how to be sure
We don’t publish inflated peak numbers. The honest picture: 102 Tb/s non-blocking at <600 ns port-to-port is sized to carry cluster collectives without becoming the bottleneck. Want certainty? Request a free scaling test of your training job across nodes on this fabric before you buy; we’ll send back real all-reduce bandwidth and scaling efficiency.
Series & scale path
- DRACO (flagship fabric tier) — this.
- Speed ladder: 200G Ethernet → 400G NDR → 800G XDR InfiniBand.
- Scale: single switch → leaf-spine fabric → full non-blocking fabric for thousands of GPUs (see RDP AI Networking fabric bundles).
On-prem vs cloud — the TCO case
An owned fabric is a one-time asset that removes the per-node networking premium of cloud GPU clusters and keeps the data path in-house. RDP pricing is fixed in INR with a GST input-credit-eligible invoice — ask for a fabric design and TCO for your cluster.
Software & integration
Integrates with the AI stack: the InfiniBand subnet manager, NCCL with SHARP, and standard MPI, with fabric monitoring and telemetry. Validated with RDP GPU servers, rack-scale systems and storage.
Power, cooling & rack integration
A 1U switch with redundant PSUs and front-to-back airflow — specify rack power, cooling and cable plant (DAC/AOC/transceivers). (Exact power draw, BTU and cabling confirmed on the build sheet.) Full out-of-band management.
Deployment, warranty & support
- Made to order, configured, cabled and validated in India as part of the cluster; lead time confirmed at quote.
- In the box: switch, rails, power cables, and the configured fabric profile; transceivers/cables scoped at quote.
- Onsite warranty + AMC with pan-India coverage and an RMA/escalation path (exact terms confirmed at quote).
Why RDP
14 years of Make-in-India infrastructure and 300,000+ devices shipped. Indian OEM, INR pricing, GST tax invoice, pan-India onsite engineers, GeM availability, and DPDP / sovereign-AI-ready deployment.
Buy with confidence
This is an AI cluster fabric switch, made to order — talk to an RDP solution architect, design the topology and oversubscription for your cluster, get a fabric TCO, and run a scaling test before you commit. Request a quote to begin.
Specifications
| Form Factor | 1U |
| Series | DRACO |
| Ports | 64× 800G OSFP (XDR) |
| Switching Capacity | 102 Tb/s |
| Fabric | InfiniBand XDR (Quantum-X800 class) |
| Port Speed | 800G / 400G |
| Port-to-Port Latency | Sub-600 ns port-to-port |
| Model fit | GPU scale-out fabric |
Why RDP GPU Mart
- ✓ Make in India OEM — Hyderabad facility, 14 years, 300,000+ devices shipped.
- ✓ Sovereign-ready: India data residency (DPDP), MeitY-recognised, ISO 27001 / SOC 2 paths.
- ✓ INR-transparent: GST invoice, CGST/SGST or IGST, pan-India onsite SLA.
- ✓ Available on GeM for government and PSU procurement.
FAQ
Is GST invoicing available?
Yes — GST invoice, CGST+SGST or IGST by billing state, eligible for input credit.
Do you deliver and install pan-India?
Yes — pan-India delivery with onsite installation and a 3-year onsite SLA.
What warranty and support is included?
3-year pan-India onsite SLA with AMC and flexible financing options.
Can this be configured to my workload?
Yes — talk to an RDP solutions architect for a custom build or multi-node cluster.
Compare the range
Other AI Networking in this line
Swipe to compare
| 64-Port 400G Infi… | 32-Node InfiniBan… | Spectrum-X 800G E… | 16-Node InfiniBan… | |
|---|---|---|---|---|
| GPUs | — | — | — | — |
| GPU memory | — | — | — | — |
| Model fit | GPU scale-out fabric | Multi-node GPU fabric | AI Ethernet & storage fabric | Multi-node GPU fabric |
| Networking | — | — | — | — |
| Chassis | — | — | — | — |
| Price | Request a Quote | Request a Quote | On request | Request a Quote |
| View | View | Quote | View |
Build the full stack
Pair it with








Designing a GPU cluster, not just one server?
Talk to an RDP solutions architect about the full fabric — networking, storage, rack and power.
*Pan-India delivery and onsite installation are subject to location serviceability; standard SLA terms apply. Specifications indicative; final configuration confirmed on quote.