DRACO 250 kW In-Rack CDU
Liquid Cooling & Thermal

DRACO 250 kW In-Rack CDU

SKU: 621126

250 kW · Up to 400 L/min · Liquid-to-liquid CDU (in-rack) · PG25 / treated water · In-rack (full-height)

Made to order
Pricing on request
No-obligation quote · typically a reply within 1 business day
Talk to sales: +91 720 794 8743
✓ 3-yr pan-India onsite SLA ✓ GST input credit ✓ Buy-back & upgrade path ✓ EMI / lease available
Pan-India delivery & onsite install*
Need volume or a custom build? Request a quote.

Key Specifications

See full specs ↓
Cooling Capacity250 kW
Flow RateUp to 400 L/min
TypeLiquid-to-liquid CDU (in-rack)
Coolant / FluidPG25 / treated water
Racks Supported1-2 dense racks
Form factorRack
300,000+ devices shipped · 14 years Make-in-India OEM · ISO 9001 · MeitY-recognised · on GeM

“RDP delivered and installed our edge AI pods across 6 sites with predictable INR pricing and onsite SLA.” — [customer / sector, to confirm]

Make in India

Designed, built and supported in India — sovereign by design

Your AI factory on sovereign Indian infrastructure: data residency under DPDP, MeitY-recognised, ISO 27001 / SOC 2 deployment paths, and procurement on GeM.

DPDP data residencyMeitY-recognisedISO 27001 / SOC 2Available on GeMMake-in-India OEM

Overview

The DRACO 250 kW In-Rack CDU removes the heat that dense GPU racks generate — 250 kW of cooling via liquid-to-liquid cdu (in-rack), so today’s 700 W–1 kW+ GPUs run at full clocks without thermal throttling. It is the thermal layer that makes high-density AI racks possible on-premises, in INR, on a GST invoice.

Engineered to match RDP’s GPU servers, rack-scale systems and superclusters, it integrates with your facility water or runs closed-loop, and is delivered sized, plumbed and validated with the compute it cools — with leak detection and monitoring built in.

Key highlights

  • 250 kW — rack/row-level coolant distribution.
  • Liquid-to-liquid CDU (in-rack) — distributes treated coolant to cold-plate loops with filtration and control.
  • Up to 400 L/min · PG25 / treated water — controlled flow and coolant chemistry for reliable, corrosion-safe operation.
  • Leak detection & monitoring — sensors and BMS/DCIM integration for safe, observable operation.
  • Supports 1-2 dense racks — sized to the density of RDP GPU racks.
  • Quiet, efficient — liquid moves heat far more efficiently than air, lowering fan power and PUE.
  • Validated with RDP compute — delivered as part of a tested, cooled rack.
  • Make-in-India OEM — predictable INR pricing, GST tax invoice, pan-India onsite support, GeM-procurable.

Where it fits

  • Dense GPU racks (primary): feeds direct-to-chip cold-plate loops across a rack or row.
  • Rack-scale & NVL systems: the cooling that keeps NVL72-class racks within thermal limits.
  • Retrofit or new build: design a liquid-cooled hall, or add density to a room.
  • Edge/micro-DC: sealed/compact options for self-contained sites.

How it works

The unit isolates the rack coolant loop from facility water, controls flow, temperature and pressure, filters the coolant, and distributes it to the cold-plate loops. RDP sizes the loop, flow and coolant to your rack density and facility. Honest note: real cooling capacity depends on inlet water temperature, flow and rack layout — we size and validate it for your room.

Industry use cases

  • AI data centres — cool dense GPU and NVL racks at full clocks.
  • Government & national labs — sovereign HPC/AI cooling.
  • Neocloud / AI providers — higher density per rack, lower PUE.
  • Manufacturing & energy — HPC + AI thermal management.
  • Edge & remote sites — sealed liquid cooling without a facility loop.
  • Colocation — liquid-ready density in shared halls.

Performance — and how to be sure

We don’t publish inflated peak numbers. The honest picture: 250 kW at Up to 400 L/min cools dense AI racks within thermal limits given suitable conditions. Want certainty? Request a thermal assessment of your racks and room before you buy; we’ll size the solution and confirm the cooling capacity at your conditions.

Series & scale path

  • DRACO (flagship thermal tier) — this.
  • Capacity ladder: rear-door HX → in-rack/in-row CDU → row CDU → facility CDU (MW-scale).
  • When to step up: grow from rack to row to facility cooling as density rises — talk to an architect about the loop.

Liquid vs air — the efficiency case

At 700 W–1 kW+ per GPU, air cooling hits its limit; liquid removes heat far more efficiently, enabling higher density, full clocks and lower PUE — and quieter rooms. The result is more compute per rack and lower energy cost. RDP pricing is fixed in INR with a GST input-credit-eligible invoice — ask for a PUE and density comparison for your room.

Software & integration

Integrates with your facility: BMS/DCIM monitoring, leak detection, flow/temperature/pressure telemetry, and alarms. Designed to match RDP GPU servers, rack-scale systems and superclusters.

Power, cooling & facility integration

A In-rack (full-height) unit — plan facility water (supply/return temperature and flow), power for pumps/controls, and floor/rack integration. (Exact capacity, flow, pressure-drop and connection figures confirmed in the thermal design.) Redundant pumps and monitoring available.

Deployment, warranty & support

  • Made to order, sized, plumbed and commissioned in India with the compute it cools; lead time confirmed at quote.
  • In the box: CDU, fittings, sensors and controls; facility connection scoped at quote.
  • Onsite warranty + AMC with pan-India coverage and an RMA/escalation path (exact terms confirmed at quote).

Why RDP

14 years of Make-in-India infrastructure and 300,000+ devices shipped. Indian OEM, INR pricing, GST tax invoice, pan-India onsite engineers, GeM availability, and DPDP / sovereign-AI-ready deployment.

Buy with confidence

This is AI rack cooling, made to order — talk to an RDP solution architect, get a thermal assessment and sizing for your racks and room, and a PUE comparison before you commit. Request a quote to begin.

Specifications

Form FactorRack
SeriesDRACO
Cooling Capacity250 kW
Flow RateUp to 400 L/min
TypeLiquid-to-liquid CDU (in-rack)
Coolant / FluidPG25 / treated water
Racks Supported1-2 dense racks
Model fitLiquid-cooled GPU racks

Why RDP GPU Mart

  • ✓ Make in India OEM — Hyderabad facility, 14 years, 300,000+ devices shipped.
  • ✓ Sovereign-ready: India data residency (DPDP), MeitY-recognised, ISO 27001 / SOC 2 paths.
  • ✓ INR-transparent: GST invoice, CGST/SGST or IGST, pan-India onsite SLA.
  • ✓ Available on GeM for government and PSU procurement.

FAQ

Is GST invoicing available?

Yes — GST invoice, CGST+SGST or IGST by billing state, eligible for input credit.

Do you deliver and install pan-India?

Yes — pan-India delivery with onsite installation and a 3-year onsite SLA.

What warranty and support is included?

3-year pan-India onsite SLA with AMC and flexible financing options.

Can this be configured to my workload?

Yes — talk to an RDP solutions architect for a custom build or multi-node cluster.

Compare the range

Other Liquid Cooling & Thermal in this line

Swipe to compare

40 kW Rear-Door H…100 kW In-Row CDUDirect-Liquid Coo…50 kW Direct-Liqu…
GPUs
GPU memory
Model fitAir-assist rack coolingLiquid-cooled GPU racksDirect-to-chip liquid coolingDirect-to-chip liquid cooling
Networking
Chassis
PriceRequest a QuoteOn requestRequest a QuoteRequest a Quote
ViewQuoteViewView

Build the full stack

Pair it with

Designing a GPU cluster, not just one server?

Talk to an RDP solutions architect about the full fabric — networking, storage, rack and power.

Talk to an architect

*Pan-India delivery and onsite installation are subject to location serviceability; standard SLA terms apply. Specifications indicative; final configuration confirmed on quote.

Pricing on requestRequest a Quote