DRACO 256x B200 SXM AI SuperCluster
AI SuperClusters

DRACO 256× B200 SXM AI SuperCluster

SKU: 159289

32× HGX B200 nodes · 64× Intel Xeon 6 (32 nodes) · 64 TB DDR5 ECC · 4 PB parallel NVMe · 4-Rack pod · liquid-cooled

Made to order
Pricing on request
No-obligation quote · typically a reply within 1 business day
Talk to sales: +91 720 794 8743
✓ 3-yr pan-India onsite SLA ✓ GST input credit ✓ Buy-back & upgrade path ✓ EMI / lease available
Pan-India delivery & onsite install*
Need volume or a custom build? Request a quote.

Key Specifications

See full specs ↓
GPUs32× HGX nodes (256× NVIDIA B200 SXM)
GPU memory~46 TB HBM3e (256× 180 GB)
Model fitFrontier multi-rack
CPU64× Intel Xeon 6 (32 nodes)
System memory64 TB DDR5 ECC
Storage4 PB parallel NVMe
NetworkingSpine-leaf InfiniBand (NDR/XDR)
Chassis4-Rack pod
300,000+ devices shipped · 14 years Make-in-India OEM · ISO 9001 · MeitY-recognised · on GeM

“RDP delivered and installed our edge AI pods across 6 sites with predictable INR pricing and onsite SLA.” — [customer / sector, to confirm]

Make in India

Designed, built and supported in India — sovereign by design

Your AI factory on sovereign Indian infrastructure: data residency under DPDP, MeitY-recognised, ISO 27001 / SOC 2 deployment paths, and procurement on GeM.

DPDP data residencyMeitY-recognisedISO 27001 / SOC 2Available on GeMMake-in-India OEM

Overview

The DRACO 256× B200 SXM AI SuperCluster is a turnkey, liquid-cooled multi-rack AI supercluster — 256 NVIDIA B200 SXM GPUs across 32 HGX nodes in a 4-rack pod, wired with a non-blocking spine-leaf InfiniBand fabric. It delivers ~46 TB HBM3e of aggregate GPU memory and arrives as a complete, validated system — power, cooling, fabric, storage and software — ready to train frontier models on-premises, in INR, on a GST invoice.

Engineered for sovereign-AI programmes, neoclouds and large enterprises building data-hall-scale capacity, it is delivered as a single engagement: RDP designs the reference architecture, integrates and burns it in, and hands over one validated supercluster with one warranty and one support contract — removing the multi-vendor integration risk of building it yourself.

Key highlights

  • 256× B200 SXM · ~46 TB HBM3e aggregate — data-hall-scale GPU memory for training and serving the largest models.
  • Non-blocking spine-leaf InfiniBand (NDR/XDR) — full-bisection bandwidth for near-linear scaling across all 32 nodes.
  • NVLink + NVSwitch within each node — full intra-node bandwidth, complemented by the InfiniBand spine between nodes.
  • 64× Intel Xeon 6 (32 nodes) + 64 TB DDR5 ECC — host compute and memory matched to 256 data-centre GPUs.
  • 4 PB parallel NVMe parallel filesystem — high-throughput training data and checkpoint storage at cluster scale.
  • 4-Rack pod, liquid-cooled, turnkey — delivered racked, cabled, cooled, validated; one SKU, one warranty.
  • On-prem data sovereignty — training data and weights stay in-house; DPDP-friendly, air-gappable.
  • Make-in-India OEM — predictable INR pricing, GST tax invoice (HSN 8471), pan-India onsite support, GeM-procurable.

AI workload fit (what it actually runs — honestly)

  • Frontier training: distributed pre-training of large foundation models across the 256 GPUs with 3D parallelism (data, tensor, pipeline).
  • Large-scale fine-tuning & serving: fine-tune and serve many large models in parallel, or shard the very largest across nodes.
  • RAG, multimodal & agentic platforms: production AI platforms for an entire organisation on the cluster’s storage and fabric.
  • Engineering note: at supercluster scale the limiting factor is the network, not a single GPU — this system uses a non-blocking spine-leaf InfiniBand fabric so collective (all-reduce) traffic scales. Real efficiency depends on model and parallelism strategy; we run a scaling test on your workload rather than quoting a peak FLOPS number.

AI workload positioning

This sits at the data-hall / foundation-model stage: a complete AI supercomputer rather than a server or single rack. With ~46 TB HBM3e of GPU memory on a non-blocking fabric, it is sized to sustain frontier-model training and organisation-wide serving on-prem — the sovereign, owned alternative to renting a hyperscale cloud cluster, where the meter never stops.

Industry use cases

  • Government & sovereign AI — a national foundation-model supercluster on GeM-procurable infrastructure.
  • Neocloud / AI providers — a competitive GPU-cloud region built and validated end-to-end.
  • BFSI & conglomerates — private large-model training under data-residency rules.
  • Healthcare & life sciences — large-scale research and imaging programmes, data in-house.
  • Research & national labs — an institutional AI supercomputer.
  • Telecom — in-house foundation-model and platform development at scale.

Performance — and how to be sure

We don’t publish inflated peak numbers. The honest picture: 256 B200 SXM GPUs (~46 TB HBM3e) on a non-blocking InfiniBand fabric are sized for frontier-scale distributed training and organisation-wide serving. Want certainty? Request a free scaling benchmark of your model and dataset on a representative configuration before you commit; we’ll send back real tokens/sec, scaling efficiency and projected time-to-train.

Series & upgrade path

  • DRACO (flagship supercluster tier) — this.
  • Scale ladder: 256-GPU pod → 512-GPU pod → GB200/GB300 NVL72 SuperPODs (hundreds–thousands of GPUs).
  • When to step up: for unified NVLink domains at rack scale, see RDP NVL72 Rack-Scale systems; for the largest SuperPODs, scale this fabric out — talk to an architect about the data hall.

On-prem vs cloud — the TCO case

At supercluster scale, owning is a strategic and economic decision: an always-on hyperscale cloud cluster dominates any AI budget over a multi-year horizon, while on-prem removes egress and keeps sovereign data and weights in-house. RDP pricing is fixed in INR with a GST input-credit-eligible invoice — ask for a multi-year TCO and financing model.

Software & day-one readiness

Ships pre-integrated and validated: NVIDIA driver, CUDA, cuDNN, NCCL, the InfiniBand stack, Slurm and/or Kubernetes, container registry, PyTorch and vLLM / Triton / TensorRT-LLM on Ubuntu LTS, with monitoring and a job scheduler. Optional managed cluster operations and an MLOps platform.

Power, cooling & rack integration

A 4-rack pod liquid-cooled supercluster with high power density — RDP scopes facility power, CDU/manifold and water, the InfiniBand spine, floor layout and redundancy as part of the reference-architecture design. (Exact power, BTU, flow and facility figures confirmed in the design package.) Full out-of-band management across the cluster.

Deployment, warranty & support

  • Made to order, integrated, racked, cabled, cooled and burned-in in India; project timeline confirmed at quote.
  • Delivered as one system: nodes, leaf/spine switches, cabling, PDUs, cooling, parallel storage, and the full cluster software stack.
  • Onsite warranty + AMC with pan-India coverage, cluster-level SLAs and an RMA/escalation path (exact terms confirmed at quote).

Why RDP

14 years of Make-in-India infrastructure and 300,000+ devices shipped. Indian OEM, INR pricing, GST tax invoice (HSN 8471), pan-India onsite engineers, GeM availability, and DPDP / sovereign-AI-ready deployment.

Buy with confidence

This is a turnkey AI supercluster, made to order — talk to an RDP solution architect, co-design the reference architecture, fabric and data hall, get a multi-year TCO and financing plan, and run a scaling benchmark before you commit. Request a quote to begin.

Specifications

Use CaseAgentic AI, Computer Vision, Generative AI, HPC & AI, Inference, LLM Training, Model Fine-tuning, NLP & Speech, RAG, Sovereign AI
GPU ModelNVIDIA B200 SXM
Form FactorRack
Workload FitBlackwell AI supercluster
GPUs32× HGX nodes (256× NVIDIA B200 SXM)
GPU memory~46 TB HBM3e (256× 180 GB)
Model fitFrontier multi-rack
CPU64× Intel Xeon 6 (32 nodes)
System memory64 TB DDR5 ECC
Storage4 PB parallel NVMe
NetworkingSpine-leaf InfiniBand (NDR/XDR)
Chassis4-Rack pod
GPU Count256
CoolingLiquid
SeriesDRACO

Why RDP GPU Mart

  • ✓ Make in India OEM — Hyderabad facility, 14 years, 300,000+ devices shipped.
  • ✓ Sovereign-ready: India data residency (DPDP), MeitY-recognised, ISO 27001 / SOC 2 paths.
  • ✓ INR-transparent: GST invoice, CGST/SGST or IGST, pan-India onsite SLA.
  • ✓ Available on GeM for government and PSU procurement.

FAQ

Is GST invoicing available?

Yes — GST invoice, CGST+SGST or IGST by billing state, eligible for input credit.

Do you deliver and install pan-India?

Yes — pan-India delivery with onsite installation and a 3-year onsite SLA.

What warranty and support is included?

3-year pan-India onsite SLA with AMC and flexible financing options.

Can this be configured to my workload?

Yes — talk to an RDP solutions architect for a custom build or multi-node cluster.

Compare the range

Other AI SuperClusters in this line

Swipe to compare

256× H200 SXM AI …8× GB200 NVL72 AI…32× GB300 NVL72 A…512× H200 SXM AI …
GPUs32× HGX nodes (256× NVIDIA H200 SXM5)8× GB200 NVL72 (576× Grace-Blackwell)32× GB300 NVL72 (2304× Grace-Blackwell Ultra)64× HGX nodes (512× NVIDIA H200 SXM5)
GPU memory~36 TB HBM3e (256× 141 GB)~110 TB HBM3e (576× 192 GB)~664 TB HBM3e (2,304× 288 GB)~72 TB HBM3e (512× 141 GB)
Model fitFrontier multi-rackFrontier multi-rackFrontier multi-rackFrontier multi-rack
NetworkingSpine-leaf InfiniBand (NDR/XDR)Spine-leaf InfiniBand (NDR/XDR)Spine-leaf InfiniBand (NDR/XDR)Spine-leaf InfiniBand (NDR/XDR)
Chassis4-Rack pod8-Rack SuperPODMulti-Rack data hall8-Rack pod
PriceRequest a QuoteOn requestOn requestRequest a Quote
ViewQuoteQuoteView

Build the full stack

Pair it with

Designing a GPU cluster, not just one server?

Talk to an RDP solutions architect about the full fabric — networking, storage, rack and power.

Talk to an architect

*Pan-India delivery and onsite installation are subject to location serviceability; standard SLA terms apply. Specifications indicative; final configuration confirmed on quote.

Pricing on requestRequest a Quote