

DRACO 256× MI300X AI Supercomputer
256× MI300X · 64× AMD EPYC (32 nodes) · 64 TB DDR5 ECC · 4 PB parallel NVMe · Multi-Rack · liquid-cooled
Key Specifications
See full specs ↓“RDP delivered and installed our edge AI pods across 6 sites with predictable INR pricing and onsite SLA.” — [customer / sector, to confirm]


Designed, built and supported in India — sovereign by design
Your AI factory on sovereign Indian infrastructure: data residency under DPDP, MeitY-recognised, ISO 27001 / SOC 2 deployment paths, and procurement on GeM.
Overview
The DRACO 256× MI300X AI Supercomputer is a turnkey, liquid-cooled HPC + AI supercomputer built on 256 AMD Instinct MI300X accelerators, delivering ~49 TB HBM3 of aggregate accelerator memory across a multi-rack system with a non-blocking InfiniBand spine. It is engineered for organisations that need both traditional HPC (simulation, FP64) and frontier AI on one machine — on-premises, in INR, on a GST invoice.
Delivered as a single engagement, RDP designs the reference architecture, integrates, cools and burns it in, and hands over one validated supercomputer with one warranty and one support contract — removing multi-vendor integration risk. Its defining strength: large 192 GB HBM3 per GPU for memory-bound AI.
Key highlights
- 256× MI300X · ~49 TB HBM3 aggregate — accelerator memory for large simulations and frontier AI.
- Infinity Fabric + non-blocking InfiniBand — AMD Infinity Fabric within each node and a non-blocking InfiniBand spine between nodes.
- HPC + AI convergence — strong FP64/HPC throughput alongside mixed-precision AI on one system.
- 64× AMD EPYC (32 nodes) + 64 TB DDR5 ECC — CPU and memory matched to 256 accelerators.
- 4 PB parallel NVMe parallel filesystem — high-throughput storage for datasets, checkpoints and simulation output.
- Multi-Rack, liquid-cooled, turnkey — delivered, integrated and validated; one engagement, one warranty.
- On-prem data sovereignty — data and models stay in-house; DPDP-friendly, air-gappable.
- Make-in-India OEM — predictable INR pricing, GST tax invoice (HSN 8471), pan-India onsite support, GeM-procurable.
AI workload fit (what it actually runs — honestly)
- HPC + simulation: FP64 scientific computing (CFD, weather, molecular dynamics, finite-element) alongside AI.
- Frontier AI training: distributed training of large models across the 256 accelerators with 3D parallelism.
- Large-scale inference & fine-tuning: serve and fine-tune many large models in parallel.
- Engineering note: this is an AMD Instinct system: it runs the open ROCm/HIP software stack, not CUDA — we validate your models and HPC codes on ROCm before you commit. At this scale the network and parallelism strategy decide real performance; we run a scaling test on your codes and models rather than quoting a peak number.
AI workload positioning
This sits at the HPC + foundation-model convergence: a supercomputer that runs both scientific simulation and frontier AI. With ~49 TB HBM3 of accelerator memory on a non-blocking fabric, it is sized to sustain mixed HPC/AI workloads on-prem — the sovereign, owned alternative to renting hyperscale capacity.
Industry use cases
- Government & national labs — a sovereign HPC + AI supercomputer on GeM-procurable infrastructure.
- Weather, climate & energy — large FP64 simulation plus AI surrogates.
- Pharma & life sciences — molecular dynamics, drug discovery and AI in one system.
- Aerospace, automotive & manufacturing — CFD/FEA simulation plus AI design.
- Academia & research — a shared institutional supercomputer for HPC and AI.
- Neocloud / HPC providers — a converged HPC+AI service platform.
Performance — and how to be sure
We don’t publish inflated peak numbers. The honest picture: 256 MI300X accelerators (~49 TB HBM3) on a non-blocking fabric are sized for converged HPC + AI at scale. Want certainty? Request a free benchmark — your HPC codes and AI models, including a scaling test — on a representative configuration before you commit; we’ll send back real performance and scaling efficiency.
Series & upgrade path
- DRACO (flagship supercomputer tier) — this.
- Scale ladder: from a few hundred accelerators to exascale-class systems (thousands of accelerators).
- Architecture options: NVIDIA Grace-Hopper, AMD Instinct MI300X/MI300A — chosen to fit your codes and software stack.
- When to step up: extend to a larger data hall — co-design the fabric, power and facility with an RDP architect.
On-prem vs cloud — the TCO case
At supercomputer scale, owning is a strategic and economic decision: an always-on hyperscale cloud system dominates any budget over a multi-year horizon, while on-prem removes egress and keeps sovereign data and codes in-house. RDP pricing is fixed in INR with a GST input-credit-eligible invoice — ask for a multi-year TCO and financing model.
Software & day-one readiness
Ships pre-integrated and validated: AMD ROCm, HIP, RCCL, the InfiniBand stack, Slurm and/or Kubernetes, with PyTorch (ROCm) and vLLM (ROCm) on a supported Linux LTS, with monitoring and a scheduler. Optional managed operations and an HPC/MLOps platform.
Power, cooling & rack integration
A multi-rack liquid-cooled supercomputer with high power density — RDP scopes facility power, CDU/manifold and water, the InfiniBand spine, floor layout and redundancy in the reference-architecture design. (Exact power, BTU, flow and facility figures confirmed in the design package.) Full out-of-band management.
Deployment, warranty & support
- Made to order, integrated, racked, cabled, cooled and burned-in in India; project timeline confirmed at quote.
- Delivered as one system: nodes, leaf/spine switches, cabling, PDUs, cooling, parallel storage, and the full HPC/AI software stack.
- Onsite warranty + AMC with pan-India coverage, system-level SLAs and an escalation path (exact terms confirmed at quote).
Why RDP
14 years of Make-in-India infrastructure and 300,000+ devices shipped. Indian OEM, INR pricing, GST tax invoice (HSN 8471), pan-India onsite engineers, GeM availability, and DPDP / sovereign-AI-ready deployment.
Buy with confidence
This is a turnkey HPC + AI supercomputer, made to order — talk to an RDP solution architect, co-design the architecture for your codes and models, get a multi-year TCO, and run a benchmark before you commit. Request a quote to begin.
Specifications
| Use Case | Agentic AI, Computer Vision, Generative AI, HPC & AI, Inference, LLM Training, Model Fine-tuning, NLP & Speech, RAG, Sovereign AI |
| GPU Model | AMD Instinct MI300X |
| Form Factor | Rack |
| Workload Fit | AMD Instinct AI supercomputer |
| GPUs | 256× AMD Instinct MI300X |
| GPU memory | ~49 TB HBM3 (256× 192 GB) |
| Model fit | HPC + frontier AI |
| CPU | 64× AMD EPYC (32 nodes) |
| System memory | 64 TB DDR5 ECC |
| Storage | 4 PB parallel NVMe |
| Networking | Infinity Fabric + InfiniBand (NDR) |
| Chassis | Multi-Rack |
| GPU Count | 256 |
| Cooling | Liquid |
| Series | DRACO |
Why RDP GPU Mart
- ✓ Make in India OEM — Hyderabad facility, 14 years, 300,000+ devices shipped.
- ✓ Sovereign-ready: India data residency (DPDP), MeitY-recognised, ISO 27001 / SOC 2 paths.
- ✓ INR-transparent: GST invoice, CGST/SGST or IGST, pan-India onsite SLA.
- ✓ Available on GeM for government and PSU procurement.
FAQ
Is GST invoicing available?
Yes — GST invoice, CGST+SGST or IGST by billing state, eligible for input credit.
Do you deliver and install pan-India?
Yes — pan-India delivery with onsite installation and a 3-year onsite SLA.
What warranty and support is included?
3-year pan-India onsite SLA with AMC and flexible financing options.
Can this be configured to my workload?
Yes — talk to an RDP solutions architect for a custom build or multi-node cluster.
Compare the range
Other Supercomputers in this line
Swipe to compare
| 256× GH200 AI Sup… | 4096× MI300A AI S… | 8192× MI300A AI S… | 512× GH200 AI Sup… | |
|---|---|---|---|---|
| GPUs | 256× NVIDIA GH200 Grace-Hopper | 4096× AMD Instinct MI300A | 8192× AMD Instinct MI300A | 512× NVIDIA GH200 Grace-Hopper |
| GPU memory | ~37 TB HBM3e (256× 144 GB) | ~524 TB unified HBM3 (4,096× 128 GB) | ~1.0 PB unified HBM3 (8,192× 128 GB) | ~74 TB HBM3e (512× 144 GB) |
| Model fit | HPC + frontier AI | HPC + frontier AI | HPC + frontier AI | HPC + frontier AI |
| Networking | NVLink-C2C + InfiniBand (NDR/XDR) | Infinity Fabric + InfiniBand (NDR) | Infinity Fabric + InfiniBand (NDR) | NVLink-C2C + InfiniBand (NDR/XDR) |
| Chassis | Multi-Rack | Multi-Rack data hall | Data hall | Multi-Rack |
| Price | Request a Quote | On request | On request | Request a Quote |
| View | Quote | Quote | View |
Build the full stack
Pair it with








Designing a GPU cluster, not just one server?
Talk to an RDP solutions architect about the full fabric — networking, storage, rack and power.
*Pan-India delivery and onsite installation are subject to location serviceability; standard SLA terms apply. Specifications indicative; final configuration confirmed on quote.