DRACO ORv3 140 kW NVL72-Class AI Rack
Key Specifications
See full specs ↓“RDP delivered and installed our edge AI pods across 6 sites with predictable INR pricing and onsite SLA.” — [customer / sector, to confirm]


Designed, built and supported in India — sovereign by design
Your AI factory on sovereign Indian infrastructure: data residency under DPDP, MeitY-recognised, ISO 27001 / SOC 2 deployment paths, and procurement on GeM.
Overview
The rack an NVL72-class system actually needs. A GB300 NVL72 or a 72-GPU rack-scale AI system draws roughly 135–142 kW sustained — well past what a 19-inch EIA rack on legacy AC distribution can feed or cool. This is the 21-inch OCP Open Rack v3 frame, 48 V DC busbar and direct-to-chip liquid loop that a rack-scale AI system is designed to drop into.
Key highlights
- 21″ OCP Open Rack v3 (ORv3) — the open standard NVL72-class racks are built on.
- 140 kW rack capacity — sized for a full rack-scale AI system, not retrofitted to one.
- 48 V DC busbar with blind-mate connectors — no per-server power cords, no stranded power.
- 4× 30 kW power shelves, N+1 — the ORv3 shelf architecture, AC→48V DC rectification.
- 480 V 3-phase input {VERIFY per site} with 2N upstream feed options.
- Direct-to-chip liquid ready — manifolds, blind-mate quick-disconnects, in-row CDU.
- Integrated, populated and commissioned in India by RDP.
AI workload fit
- Housing a GB300 NVL72 or equivalent rack-scale AI system.
- Housing a 72× MI455X or other 70-plus-GPU open-fabric rack.
- LLM training and inference at rack scale.
- Sovereign AI facility builds on open, non-proprietary rack standards.
- HPC & AI datacenters moving from 19″ EIA to OCP.
- AI-factory pods where every rack is identical and serviceable.
AI workload positioning
Most Indian datacenters are 19-inch EIA at 10–20 kW per rack. A rack-scale AI system needs roughly seven times that in a different physical standard, and the mismatch is where AI projects stall — the compute arrives and the facility cannot take it. Open Rack v3 (ORv3) is the Open Compute Project’s high-density rack standard: a 21-inch rack aperture instead of the legacy 19-inch EIA, a 48 V DC busbar running the full height of the rack, and blind-mate power connectors so servers slide in without individual power cords. Capacity is measured in OU (OpenU, 48 mm) rather than RU. The 48 V DC architecture raises usable power density substantially over legacy per-server AC distribution, which is what makes 100 kW-plus racks practical at all. RDP sells this as the matched pair to the compute, and will tell you plainly if your building is not ready for it. A facility survey is mandatory before order.
Industry use cases
- Neocloud: standardised, repeatable ORv3 rack units across a growing fleet.
- Public sector & sovereign: national AI facilities built on open standards, not one vendor’s rack.
- Enterprise & GCCs: the first rack-scale AI deployment in an existing datacenter.
- Research & education: housing a national or institutional rack-scale system.
- Telecom: AI capacity inside existing central-office and edge facilities.
Performance & how to be sure
The figure that governs everything here is kW per rack: 140 kW is roughly 7× a conventional 20 kW enterprise rack, and it is why liquid cooling and a 48 V busbar stop being optional. Rather than quote a tokens/sec figure that will not match your workload, RDP offers a “benchmark your model” session: bring the model, precision and context length you actually intend to run, and we will validate it on this exact configuration before you commit.
Series & upgrade path
Below: the DRACO 48U 100 kW 19″ EIA liquid-ready rack for dense-but-not-rack-scale builds. Above: the DRACO ORv3 480 kW AI Factory Rack. Pairs with RDP in-row CDUs and the DRACO 250 kW Power & UPS Block, and with Rack Integration & Deployment services.
On-prem vs cloud (TCO)
For sustained daily AI work this configuration removes per-GPU-hour billing, queueing for scarce instances, and egress charges on your own data — and keeps everything on-premises for DPDP and data-residency obligations. Cloud still wins for burst capacity and one-off very large training runs; on-prem wins on sustained utilisation, control and predictable INR capital cost. We model the crossover with your actual usage rather than assert it.
Software & day-one readiness
Rack-level monitoring covers busbar current, per-shelf load, coolant inlet/outlet temperature and leak detection, exported to your DCIM or to RDP’s managed monitoring. Power-shelf and CDU telemetry is available over Redfish/OpenBMC-compatible interfaces.
Power, thermal & acoustics
480 V 3-phase input to 4× 30 kW ORv3 rectifier shelves (N+1) feeding a 48 V DC busbar. Direct-to-chip liquid loop with rack manifold and blind-mate quick-disconnects; residual air load handled by rear-door HX or room cooling. Floor loading, water quality, flow rate and upstream switchgear are all surveyed before order — this is a facility project. Exact wattage, BTU and dB(A) figures come from RDP bench measurement rather than estimates — ask for the site-readiness sheet with your quote.
Deployment, warranty & support
Built to order by RDP Technologies. Supplied with GST invoice (HSN 8471), pan-India onsite support, and availability through GeM for public-sector procurement. Built to order — typically 10–14 weeks including facility survey and integration.
Why RDP
RDP Technologies is a Make-in-India OEM with 14+ years and 300,000+ units shipped, supplying AI infrastructure from desk-side systems to rack-scale AI factories — with predictable INR pricing, GST invoicing and pan-India onsite service.
Buy with confidence
Use Request a Quote to reach an RDP solution architect for sizing, a benchmark-your-model session, financing options and a delivery plan. No obligation.
Specifications
| Power Capacity | 140 kW per rack |
| Redundancy | N+1 power shelves · 2N feed option |
| Rack Units / Footprint | ~44 OU · 21″ OCP ORv3 |
| Distribution | 48V DC busbar · 4× 30 kW shelves · 480V 3-ph in |
| Model fit | NVL72-class rack-scale AI |
| Form Factor | Rack |
| Cooling | Liquid |
| Series | DRACO |
| Use Case | HPC & AI, Inference, LLM Training, Sovereign AI |
| Industry | Enterprise & GCCs, Neocloud, Public Sector & Sovereign, Research & Education, Telecom & 5G |
| Rack Standard | OCP Open Rack v3 (ORv3) — 21″ aperture, OU pitch |
| Power Architecture | 48 V DC busbar, blind-mate, 4× 30 kW shelves (N+1) |
| Cooling | Direct-to-chip liquid + rack manifold; RDHx for residual air load |
| Warranty & Support | RDP pan-India onsite · GST invoice · available on GeM |
Why RDP GPU Mart
- ✓ Make in India OEM — Hyderabad facility, 14 years, 300,000+ devices shipped.
- ✓ Sovereign-ready: India data residency (DPDP), MeitY-recognised, ISO 27001 / SOC 2 paths.
- ✓ INR-transparent: GST invoice, CGST/SGST or IGST, pan-India onsite SLA.
- ✓ Available on GeM for government and PSU procurement.
FAQ
Is GST invoicing available?
Yes — GST invoice, CGST+SGST or IGST by billing state, eligible for input credit.
Do you deliver and install pan-India?
Yes — pan-India delivery with onsite installation and a 3-year onsite SLA.
What warranty and support is included?
3-year pan-India onsite SLA with AMC and flexible financing options.
Can this be configured to my workload?
Yes — talk to an RDP solutions architect for a custom build or multi-node cluster.
Compare the range
Other Datacenter Infrastructure in this line
Swipe to compare
| QUASAR 42U 33 kW … | DRACO 250 kW Powe… | DRACO Rack Integr… | QUASAR 42U 20 kW … | |
|---|---|---|---|---|
| GPUs | — | — | — | — |
| GPU memory | — | — | — | — |
| Model fit | AI rack power distribution | Backup power for AI racks | Deployment & commissioning | AI rack power distribution |
| Networking | — | — | — | — |
| Chassis | — | — | — | — |
| Price | Request a Quote | On request | On request | Request a Quote |
| View | Quote | Quote | View |
Build the full stack
Pair it with








Designing a GPU cluster, not just one server?
Talk to an RDP solutions architect about the full fabric — networking, storage, rack and power.
*Pan-India delivery and onsite installation are subject to location serviceability; standard SLA terms apply. Specifications indicative; final configuration confirmed on quote.