DRACO 48U 100 kW Liquid-Ready AI Rack
Datacenter Infrastructure

DRACO ORv3 140 kW NVL72-Class AI Rack

SKU: 950140
21″ OCP ORv3 · 140 kW · 48V DC busbar · 4× 30 kW shelves (N+1) · direct-to-chip liquid
Made to order
Pricing on request
No-obligation quote · typically a reply within 1 business day
Talk to sales: +91 720 794 8743
✓ RDP pan-India onsite · GST invoice · available on GeM ✓ GST input credit ✓ Buy-back & upgrade path ✓ EMI / lease available
Pan-India delivery & onsite install*
Need volume or a custom build? Request a quote.

Key Specifications

See full specs ↓
Power Capacity140 kW per rack
RedundancyN+1 power shelves · 2N feed option
Rack Units / Footprint~44 OU · 21″ OCP ORv3
Distribution48V DC busbar · 4× 30 kW shelves · 480V 3-ph in
CoolingLiquid
Form factorRack
300,000+ devices shipped · 14 years Make-in-India OEM · ISO 9001 · MeitY-recognised · on GeM

“RDP delivered and installed our edge AI pods across 6 sites with predictable INR pricing and onsite SLA.” — [customer / sector, to confirm]

Make in India

Designed, built and supported in India — sovereign by design

Your AI factory on sovereign Indian infrastructure: data residency under DPDP, MeitY-recognised, ISO 27001 / SOC 2 deployment paths, and procurement on GeM.

DPDP data residencyMeitY-recognisedISO 27001 / SOC 2Available on GeMMake-in-India OEM

Overview

The rack an NVL72-class system actually needs. A GB300 NVL72 or a 72-GPU rack-scale AI system draws roughly 135–142 kW sustained — well past what a 19-inch EIA rack on legacy AC distribution can feed or cool. This is the 21-inch OCP Open Rack v3 frame, 48 V DC busbar and direct-to-chip liquid loop that a rack-scale AI system is designed to drop into.

Key highlights

  • 21″ OCP Open Rack v3 (ORv3) — the open standard NVL72-class racks are built on.
  • 140 kW rack capacity — sized for a full rack-scale AI system, not retrofitted to one.
  • 48 V DC busbar with blind-mate connectors — no per-server power cords, no stranded power.
  • 4× 30 kW power shelves, N+1 — the ORv3 shelf architecture, AC→48V DC rectification.
  • 480 V 3-phase input {VERIFY per site} with 2N upstream feed options.
  • Direct-to-chip liquid ready — manifolds, blind-mate quick-disconnects, in-row CDU.
  • Integrated, populated and commissioned in India by RDP.

AI workload fit

  • Housing a GB300 NVL72 or equivalent rack-scale AI system.
  • Housing a 72× MI455X or other 70-plus-GPU open-fabric rack.
  • LLM training and inference at rack scale.
  • Sovereign AI facility builds on open, non-proprietary rack standards.
  • HPC & AI datacenters moving from 19″ EIA to OCP.
  • AI-factory pods where every rack is identical and serviceable.

AI workload positioning

Most Indian datacenters are 19-inch EIA at 10–20 kW per rack. A rack-scale AI system needs roughly seven times that in a different physical standard, and the mismatch is where AI projects stall — the compute arrives and the facility cannot take it. Open Rack v3 (ORv3) is the Open Compute Project’s high-density rack standard: a 21-inch rack aperture instead of the legacy 19-inch EIA, a 48 V DC busbar running the full height of the rack, and blind-mate power connectors so servers slide in without individual power cords. Capacity is measured in OU (OpenU, 48 mm) rather than RU. The 48 V DC architecture raises usable power density substantially over legacy per-server AC distribution, which is what makes 100 kW-plus racks practical at all. RDP sells this as the matched pair to the compute, and will tell you plainly if your building is not ready for it. A facility survey is mandatory before order.

Industry use cases

  • Neocloud: standardised, repeatable ORv3 rack units across a growing fleet.
  • Public sector & sovereign: national AI facilities built on open standards, not one vendor’s rack.
  • Enterprise & GCCs: the first rack-scale AI deployment in an existing datacenter.
  • Research & education: housing a national or institutional rack-scale system.
  • Telecom: AI capacity inside existing central-office and edge facilities.

Performance & how to be sure

The figure that governs everything here is kW per rack: 140 kW is roughly 7× a conventional 20 kW enterprise rack, and it is why liquid cooling and a 48 V busbar stop being optional. Rather than quote a tokens/sec figure that will not match your workload, RDP offers a “benchmark your model” session: bring the model, precision and context length you actually intend to run, and we will validate it on this exact configuration before you commit.

Series & upgrade path

Below: the DRACO 48U 100 kW 19″ EIA liquid-ready rack for dense-but-not-rack-scale builds. Above: the DRACO ORv3 480 kW AI Factory Rack. Pairs with RDP in-row CDUs and the DRACO 250 kW Power & UPS Block, and with Rack Integration & Deployment services.

On-prem vs cloud (TCO)

For sustained daily AI work this configuration removes per-GPU-hour billing, queueing for scarce instances, and egress charges on your own data — and keeps everything on-premises for DPDP and data-residency obligations. Cloud still wins for burst capacity and one-off very large training runs; on-prem wins on sustained utilisation, control and predictable INR capital cost. We model the crossover with your actual usage rather than assert it.

Software & day-one readiness

Rack-level monitoring covers busbar current, per-shelf load, coolant inlet/outlet temperature and leak detection, exported to your DCIM or to RDP’s managed monitoring. Power-shelf and CDU telemetry is available over Redfish/OpenBMC-compatible interfaces.

Power, thermal & acoustics

480 V 3-phase input to 4× 30 kW ORv3 rectifier shelves (N+1) feeding a 48 V DC busbar. Direct-to-chip liquid loop with rack manifold and blind-mate quick-disconnects; residual air load handled by rear-door HX or room cooling. Floor loading, water quality, flow rate and upstream switchgear are all surveyed before order — this is a facility project. Exact wattage, BTU and dB(A) figures come from RDP bench measurement rather than estimates — ask for the site-readiness sheet with your quote.

Deployment, warranty & support

Built to order by RDP Technologies. Supplied with GST invoice (HSN 8471), pan-India onsite support, and availability through GeM for public-sector procurement. Built to order — typically 10–14 weeks including facility survey and integration.

Why RDP

RDP Technologies is a Make-in-India OEM with 14+ years and 300,000+ units shipped, supplying AI infrastructure from desk-side systems to rack-scale AI factories — with predictable INR pricing, GST invoicing and pan-India onsite service.

Buy with confidence

Use Request a Quote to reach an RDP solution architect for sizing, a benchmark-your-model session, financing options and a delivery plan. No obligation.

Specifications

Power Capacity140 kW per rack
RedundancyN+1 power shelves · 2N feed option
Rack Units / Footprint~44 OU · 21″ OCP ORv3
Distribution48V DC busbar · 4× 30 kW shelves · 480V 3-ph in
Model fitNVL72-class rack-scale AI
Form FactorRack
CoolingLiquid
SeriesDRACO
Use CaseHPC & AI, Inference, LLM Training, Sovereign AI
IndustryEnterprise & GCCs, Neocloud, Public Sector & Sovereign, Research & Education, Telecom & 5G
Rack StandardOCP Open Rack v3 (ORv3) — 21″ aperture, OU pitch
Power Architecture48 V DC busbar, blind-mate, 4× 30 kW shelves (N+1)
CoolingDirect-to-chip liquid + rack manifold; RDHx for residual air load
Warranty & SupportRDP pan-India onsite · GST invoice · available on GeM

Why RDP GPU Mart

  • ✓ Make in India OEM — Hyderabad facility, 14 years, 300,000+ devices shipped.
  • ✓ Sovereign-ready: India data residency (DPDP), MeitY-recognised, ISO 27001 / SOC 2 paths.
  • ✓ INR-transparent: GST invoice, CGST/SGST or IGST, pan-India onsite SLA.
  • ✓ Available on GeM for government and PSU procurement.

FAQ

Is GST invoicing available?

Yes — GST invoice, CGST+SGST or IGST by billing state, eligible for input credit.

Do you deliver and install pan-India?

Yes — pan-India delivery with onsite installation and a 3-year onsite SLA.

What warranty and support is included?

3-year pan-India onsite SLA with AMC and flexible financing options.

Can this be configured to my workload?

Yes — talk to an RDP solutions architect for a custom build or multi-node cluster.

Compare the range

Other Datacenter Infrastructure in this line

Swipe to compare

QUASAR 42U 33 kW …DRACO 250 kW Powe…DRACO Rack Integr…QUASAR 42U 20 kW …
GPUs
GPU memory
Model fitAI rack power distributionBackup power for AI racksDeployment & commissioningAI rack power distribution
Networking
Chassis
PriceRequest a QuoteOn requestOn requestRequest a Quote
ViewQuoteQuoteView

Build the full stack

Pair it with

Designing a GPU cluster, not just one server?

Talk to an RDP solutions architect about the full fabric — networking, storage, rack and power.

Talk to an architect

*Pan-India delivery and onsite installation are subject to location serviceability; standard SLA terms apply. Specifications indicative; final configuration confirmed on quote.

Pricing on requestRequest a Quote